High Temperature Fans

Different types and ranges of high temperature fans are available.
There are fans that are ideal for high temperature fumes (industrial processes etc..) or are according to European Standard EN 12101-3 which mainly concerns buildings open to public where SMOKE needs to be exhaust in case of fire. 
Here below are few examples. 

Conduct us for selection and/or advice according to requirement.

Explanation of High Temperature fans.pdf


 TURBOCAMINO series

CVT HT series

AXIA AI HT series 

PVI HT series



• 
Centrifugal chimney fan to
  extract hot and dusty fumes.

 Suitable for use on fireplaces,
  barbeque, ovens and/or 
  industrial hoods.

 Designed to extract smoke and dusty fumes at temperature up to 200° C.

 Induction motor on ball
  bearings, IP 55 protection,
  class F insulation and fitted
  with cooling impeller. 



• 
F 400 class (400° C for 2
   hours)
.

 Capacity: 1500-35000 m3/h.

 Operating pressure:
   100-1800 Pa.

 Full compliance with
   EN12101-3.



• 
F 400 class (400° C for 2
   hours)
.

• 
F 300 class (300°C for
  1 hour)
.

• 
Continuous operation 40°C 

 Capacity: up to 20000 m3/h.

 Full compliance with
   EN12101-3.


                       



 Induction fans for forced ventilation at parking.

 
F 300 class (300°C for
  2 hours)
.

• 
Continuous operation 40°C

 Full compliance with
   EN12101-3







                       

Leaflet TURBOCAMINO.pdf Leaflet CVT HT.pdf Leaflet AXIA AI HT.pdf Leaflet PVI HT.pdf

TXP 400 2H series

TXV 400 2H series 

SIB-400-2H range 

BCE range 


 
• In accordance with European
  Standard: EN 12101 – 3.

 Max temperature of the
  extracted air in continuous: 60°

 Max temperature of the
  extracted air in case of fire:
  400° only for 2 hours.

 Working temperature range:
   –  20° + 60°

 Self cleaning backward
  centrifugal impeller.



• In accordance with European
  Standard: EN 12101 – 3.

 Max temperature of the
  extracted air in continuous: 60°

 Max temperature of the
  extracted air in case of fair:
  400° only for 2 hours.

 Working temperature range:
   –  20° + 60°

Self cleaning backward
  centrifugal impeller.



This range is particularly suitable for the exhaust of large volume of high temperature air at medium to high pressure.
The unit can handle contaminated air (dust or oil).

 Centrifugal, backward curved
  impeller.

• “Single inlet” 


 
Motor can be selected based
  on the exact requirement.


 This range can be used for many heavy industrial applications

Flow: up to 250,000 m3/h 

 Pressure: up to 3500 Pa. 

 Centrifugal, backward curved
  impeller.


 Motor can be selected based
  on the exact requirement.

 

Brief description.pdf Brief description.pdf
Leaflet TXP 400 2H.pdf Leaflet TXV 400 2H.pdf Leaflet SIB-400-2H.pdf
 

VELONE range  

 CYCLONE range

 

BOX-HT range

 

 



 In accordance with European
  Standard: EN 12201 – 3 (400° 
  for 2 hours).

 Up to 27000 m3/h

 Pre-wired at the factory

 Full range of accessories
 



 In accordance with European
  Standard: EN 12201 – 3 (400°
  for 2 hours).

 Up to 32000 m3/h

 Pre-wired at the factory

 Full range of accessories

 Belt driven – forward curved
  impeller





Brief description.pdf Brief description.pdf Brief description.pdf

 

EXONE range   

SV 1V series

 

ALIZONE Fan casing

 

 



In accordance with European 
  Standard: EN 12201 – 3 (400°
  for 2 hours).

 Flow: 100 to 18500 m3/h and 
  Pressures: 50 to 1100 Pa. 

 Full range of accessories

 Direct driven – backward
  curved impeller

 



Available capacities

 Flow: 910 m3/h and  (1 –
  speed)

 Centrifugal chimney fan to 
  extract hot dusty fumes.

 Designed to extract smoke at
  temperature up to 200° C
  and 400° C for 2 hours.

 For all chimneys with
  insufficient up draught.

Variable speed controller
  available.



Air exhaust/air supply: up to
  10000 m3/h 

 Connections in-line.

 Circular casing

 Forward curved fan rear
  mounted on rails


 Indoor/ outdoor.

 Casing in galvanized steel
   with in-line circular 
   connections.

 

Brief description.pdf Brief description.pdf Brief description.pdf

HELIONE F200 (short)

 

 HELIONE F200 (long)

 

 HELIONE F400 (short shell)

 

 HELIONE F400 (long shell)



 In accordance with European
  Standard: EN 12201 – 
  3 (400° for 2 hours).

• Up to 70000 m3/h

 
Suitable for car parks,
  Commercial & Industrial
  premises

• Full range of accessories
 



 In accordance with European
  Standard: EN 12201 – 3 (400°
  for 2 hours).

 Up to 70000 m3/h

 Suitable for car parks,
  Commercial & Industrial
  premises
 
 Full range of accessories



 In accordance with European
  Standard: EN 12201 – 3 (400°
  for 2 hours).

 Up to 70000 m3/h

 Suitable for car parks,
  Commercial & Industrial
  premises

 Full range of accessories



 In accordance with European
  Standard: EN 12201 – 3 (400°
  for 2 hours).

 Up to 70000 m3/h

 Suitable for car parks,
  Commercial & Industrial
  premises

 Full range of accessories

       

DUCT M-HT range

JP-DUCT range

 JP-CENTRY range

ROOF-HP range

     